増量タイプ大腸内視鏡検査食は洗浄度を維持し高い認容性を得られるか
木本 義明港 洋平稲本 林紅林 真理絵高柳 駿也鈴木 雄一郎石井 鈴人根岸 良充小野 公平瀧田 麻衣子村元 喬大圃 研
著者情報
ジャーナル フリー

2021 年 98 巻 1 号 p. 42-44

詳細
抄録

In this study, we investigated Clear-Through® (Kewpie, Tokyo) with increased volume type.

50 patients each were enrolled in group A (Clear-Through® with increased volume type), group B (Clear-Through® with normal type) and group C (no test diet). Quality of colon cleansing in each colon was higher in both groups A and B than in group C. The quality was significantly higher (p<0.05), but there was no difference between the A/B groups. On the other hand, in the A/B group, 70/62% of patients reported that each diet tasted "good" and 76/46% of patients reported that the amount of each diet was "moderate".

Clear-Through® with increased volume type could have higher patient acceptance while maintaining colon cleansing.