Plasma and Fusion Research
Online ISSN : 1880-6821
ISSN-L : 1880-6821
Regular Articles
Development of a Simple and Tough Alpha-Particle Detector Used at High Temperature
Toshiyuki IIDAFuminobu SATOYushi KATOIppei ISHIKAWATeruya TANAKA
著者情報
ジャーナル フリー

2007 年 2 巻 p. S1085

詳細
抄録
Several ceramic detectors were made by use of the insulation layer formed on two types of substrate, i.e. aluminum and silicon. Each detector was irradiated with alpha-rays from an Am-241 source and the electric charge induced in the detector was measured in the temperature range from room temperature up to 450 K. The alpha-ray detection signals were well observed with an oscilloscope at the properly high bias-voltage only for very short time from several seconds to several tens of seconds before the start of the sweeping insulation breakdown. Though this type of the simple detector made of a thin ceramic layer can be hardly used for the energy analysis, it might be effectively applicable to the measurement of the flux of alpha-particles at high temperature.
著者関連情報
© 2007 by The Japan Society of Plasma Science and Nuclear Fusion Research
前の記事 次の記事
feedback
Top