Progress in Rehabilitation Medicine
Online ISSN : 2432-1354
ISSN-L : 2432-1354
Possible Duration of WISH-type Hip Brace Use: Prognostic Value of Timed Up and Go Test
Ena SatoTakehiko YamajiTakahisa SatoKosuke SaidaHideomi Watanabe
Author information
JOURNAL OPEN ACCESS FULL-TEXT HTML

2022 Volume 7 Article ID: 20220055

Details
Abstract

Objectives: The WISH-type S-form hip brace (WISH brace) has significantly improved hip function and functional mobility in patients with hip osteoarthritis (OA). However, most patients later undergo surgery. The main purpose of this study was to evaluate how long the orthosis can be effectively used by patients with hip OA, and to reveal the associated prognostic factors.

Methods: This prospective study examined the survival curve of the equipment by using surgery as an endpoint and investigated how the duration of use affects patients. Harris Hip Score, muscle strength, and the Timed Up and Go test (TUG) were evaluated as prognostic factors.

Results: By drawing the survival curves of 26 patients, approximately one third were expected to be still using the brace after 7 years. A rapid decrease in use was observed at around 1 year. A significant difference between patients with and without bracing at 1 year was found for the TUG result with the unaffected leg inside (ULI) at the start of bracing. A cut-off value of 9.5 s for the TUG with ULI significantly differentiated patients with and without bracing at 1 year, suggesting a possible predictor of brace survivorship in the early phase.

Conclusions: The TUG with ULI with a cut-off value of 9.5 s, or at most 10 s, may be a possible predictor of persistence of brace use in the early phase.

Content from these authors
© 2022 The Japanese Association of Rehabilitation Medicine

This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (CC BY-NC-ND) 4.0 License.
https://creativecommons.org/licenses/by-nc-nd/4.0/deed.ja
Previous article Next article
feedback
Top