Journal of Construction Management, JSCE
Online ISSN : 1884-8311
ISSN-L : 1884-8311
Risk Evaluation Method for SPSP Cutoff Walls at Coastal Waste Landfill Sites
Shinya INAZUMIHiroyasu OHTSU
Author information
JOURNAL FREE ACCESS

2008 Volume 15 Pages 13-22

Details
Abstract
An evaluation method that can express the local leakage of leachate from joint sections in steel pipc sheet pile (SPSP) cutoff walls is discussed, in this study. In particular, the evaluation of environmental feasibility (containment of leachates containing toxic substances) considering a three-dimensional arrangement and hydraulic conductivity distribution of the joint sections in the SPSP cutoff wall is compared with an evaluation that generally uses the equivalent hydraulic conductivity. This equivalent hydraulic conductivity assumes that the joint section and the steel pipe are integrated; therefore, the hydraulic conductivity is substituted with a uniform permeable layer. However, in an evaluation that employs the equivalent hydraulic conductivity, it is difficult to consider the local leakage of leachate containing toxic substances from the joint sections in the SPSP cutoff wall. This paper concluded that evaluations of the environmental feasibilities of the SPSP cutoff walls with joint sections must take into account the local leakage of leachates containing toxic substances from the joint section.
Content from these authors
© by Japan Society of Civil Engineers
Previous article Next article
feedback