Abstract
In order to obtain the basic data to analyze the material removal mechanism in the nano-grinding, the fundamental experiments to generate the nanoscale grinding grooves have been conducted using an atomic force microscope combined with a two-axis capacitive force/displacement transducer. The influences of the normal load, the loading rate and the machining speed on the formation mechanism of nanoscale grooves have been clarified.