日本生理学会大会発表要旨集
日本生理学会大会発表要旨集
セッションID: 1PIA-026
会議情報
正中神経刺激による統計的・継時的全頭型NIRS、EEGの同時測定
*竹内 幹伸高本 孝一小林 恒之河野 理石川 亮宏堀 悦郎小野 武年遠藤 俊郎西条 寿夫
著者情報
キーワード: NIRS, EEG, simultaneous
会議録・要旨集 フリー

詳細
抄録
Relationships between neuronal activities and hemodynamic responses remain unknown. We recorded simultaneously hemodynamics (Oxy-, deoxy-, and total-Hb tissue concentration) by NIRS and EEGs from the whole brain, while human subjects received the right median nerve electrical stimulation. Stimulus frequencies varied form 2 to 10 Hz. The 3-D coordinates of the NIRS probes and EEG electrodes were stereotaxically measured. Statistical significance of hemodynamic responses was evaluated by general linear model (GLM). The resultant NIRS and EEGs data were stereotaxically superimposed on the reconstructed brain of each subject. EEG data indicated that typical somatosensory evoked potentials (N21) were recorded from the contralateral somatomotor cortex. The NIRS data indicated that Oxy-Hb concentration increased at the contralateral SI area and then the responses spread to more posterior and ipsilateral areas. Comparison of these 2 data indicated that; (1) 3-D distance between dipoles of N21 and position of the channels with maximum Oxy-Hb responses was less than 10 mm, (2) the 2 topographical maps of NIRS and EEGs were significantly correlated. These results suggest usefulness of simultaneous recording of NIRS and EEGs. [J Physiol Sci. 2007;57 Suppl:S111]
著者関連情報
© 2007 日本生理学会