溶接学会論文集
Online ISSN : 2434-8252
Print ISSN : 0288-4771
炭酸ガスアーク現象に及ぼすワイヤへのREM添加の影響
片岡 時彦池田 倫正小野 守章安田 功一平田 好則
著者情報
ジャーナル フリー

2008 年 26 巻 1 号 p. 37-41

詳細
抄録
CO2gas shielded arc welding is major arc welding method, but generates large amount of spatter during welding. The root cause of spatter lies in the fact that the droplet undergoes repeated irregular shaking. To solve this problem, spatter generation modes were clarified and the effects of polarity and rare earth metal (REM) addition of the wire on CO2 gas shielded arc welding were investigated. As a result, when welding is performed with an electrode negative (DCEN) polarity using REM added wire, it was found that a conical arc plasma is formed, and the droplet which is transferred from the wire tip to the molten pool is fine and continuous, in what is termed "spray transfer". Thus, spatter generation was reduced to 10% of amount of the conventional CO2 gas shielded arc welding (from 0.058g/s to 0.005g/s).
著者関連情報