溶接学会論文集
Print ISSN : 0288-4771
溶接施工に及ぼす静的荷重の影響
-供用下における鋼橋の溶接による補修補強に関する研究-
上野 康雄李 相亨藤平 正一郎金 裕哲
著者情報
ジャーナル フリー

2010 年 28 巻 4 号 p. 391-394

詳細
抄録

The experiments under the static loads were carried out in order to investigate the possibility of repair/reinforcement by welding. Preventing the influence on the experimental devices due to the welding current by isolating between the jigs and the experimental devices, the stable experiments could be carried out. For the cruciform joints and I-shape joints, semi-auto CO2 gas welding was carried out under compressive static loads on the assumption of the dead load. As the experimental results, any cracks were not found. In the cruciform joints with multi-pass welding, there was a tendency that the longer weld length became, the larger the magnitude of out-of-plane displacement became. In the actual construction, it was verified that repair welding under static loads could be performed without welding defects by confirming repair weld length, heat input and inter-pass temperature and so on.

著者関連情報
© 2010 社団法人 溶接学会