下向溶接用鋼スタッドの横向溶接への適用に関する基礎的研究
中世古 圭基内田 拓磨鈴木 実平川上 博士OZAKI Hitoshi
著者情報
ジャーナル フリー

2016 年 34 巻 3 号 p. 204-209

詳細
抄録

In recent years, manufacturing sites have strongly requested for the steel stud with large diameter to be welded in the horizontal position, which is difficult because of gravity. In this study, the steel stud of 19mm in diameter was welded horizontally to the mild steel plate by using ferrule for usage in flat position. As results two kinds of weld defect were observed; lack of fusion and blowhole. The former occurred in the welding condition of too small or too large heat input, and the latter did in the range of longer arc time. Therefore, the suitable welding condition could be found in the large current and shorter arc time. When the areal ratio of weld defect to the cross section of stud was lower than 10 percent, the welded joint had enough statical strength.

著者関連情報
© 2016 社団法人 溶接学会