RADIOISOTOPES
Online ISSN : 1884-4111
Print ISSN : 0033-8303
ISSN-L : 0033-8303
Note
Calculation of the Effective Dose Transmissions for 125I and 241Am
Shigeo FUKANO
Author information
JOURNAL OPEN ACCESS

2012 Volume 61 Issue 1 Pages 9-19

Details
Abstract
The Radioisotope Pocket Data Book 11th edition gives values of the effective dose rate constants for two photon energy ranges of over 10keV and over 30keV.
To see the differences of the effective dose transmissions between above mentioned two energy ranges, over 10keV and over 30keV, we calcurated those for 125I and 241Am with five shielding materials, water, concrete, aluminum, iron, lead. Our new calcurated values were compared with conventionally used values.
Content from these authors
© 2012 by Japan Radioisotope Association
Previous article Next article
feedback