RADIOISOTOPES
Online ISSN : 1884-4111
Print ISSN : 0033-8303
ISSN-L : 0033-8303
The Measurement of Glomerular Filtration Rate with 169Yb-DTPA
Masataka UEDAMakoto MIKIToyohei MACHIDATakeshi MINAMIYoshiyuki MIURAHiroshi YAMADAAkira TANAKAGoro URAKUBO
Author information
JOURNAL FREE ACCESS

1972 Volume 21 Issue 9 Pages 566-573

Details
Abstract
We performed simultaneous GFR clearance method, using 169Yb-DTPA and sodium thiosulfate. The purity of agent and its urinary metabolites of rats were examined by ratio thin layer chromatography using a mixture of acetone and water (1: 1) . The solvent system appeared to be the most suitable from the point of short developing time, proper Rf value and good separating power. Whole body retention of 169Yb-DTPA in female albino rats . was studied for 41 days. While the residue (5%) was excreted very slowly and about 2% of dose still remained even on 30th day. The distribution of 169Yb-DTPA was recognized mainly' in the bone, liver and lung by autoradiogram of mice.
In man, 80-90% of the intravenously administered 169Yb-DTPA was excreted in the urine for the first 2 hours. The renal scintigrams were obtained by administrating 169Yb-DTPA; but the visualization was different from that of 203Hg-chlormerodrin.
In 23 patients, the relative coefficient of 169Yb-DTPA/sodium thiosulfate, (in the terms of clearance) was calculated at 0.98.
Content from these authors
© Japan Radioisotope Association
Previous article Next article
feedback
Top