111In-DTPAによる腎機能検査
99mTc-DTPAとの比較―
山下 正人宮崎 忠芳大野 浩司藤田 正人田中 州鶴中田 美保子渡辺 充子岡本 邦雄田畑 則之
著者情報
ジャーナル フリー

1983 年 32 巻 4 号 p. 167-170

詳細
抄録

Technetium-99m-diethylene-triamine penta-acetic acid (DTPA) and 111In-DTPA were injected simultaneously into 21 patients with various levels of renal function. Scintiphoto, camera data renograms and clearance values (plasma sampling) were obtained for each patient.
The mixed isotope scintiphoto images were of intermediate quality and the images with 111In-DTPA were apparently inferior to those with 99mTc-DTPA.
These equations were obtained:
(1) y=0.30+0.91x (coefficiency of correlation r=0.98) where x is the value at T peak (time of maximum count on renogram) obtained with 99mTc-DTPA and where y is the value at T peak with 111In-DTPA.
(2) y=-0.09+1.006x (r=0.99) where x is the value at T3/4 (time interval between the time of maximum count to the time of 3/4 of maximum count on renogram) and where y is the value at T3/4 obtained with 111In-DTPA.
(3) y=-0.01+1.007x (r=0.98) where the x and y values were for the excretion ratios (counts at 20 min/maximum counts on renogram) .
(4) y=0.81+0.98x (r=0.99) where x and y are the clearance values.

著者関連情報