RADIOISOTOPES
Online ISSN : 1884-4111
Print ISSN : 0033-8303
ISSN-L : 0033-8303
ラドカラーフィルムを用いたオートラジオグラフィ法による60Co密封線源の内部構造の検査
大西 徳博岡本 信一古田 純一郎平岡 英一
著者情報
ジャーナル フリー

1985 年 34 巻 3 号 p. 151-154

詳細
抄録

In studies using 60Co gamma-ray irradiation, an extremely high dose rate is often required and samples must be placed very near a 60Co source. The dose rate in the vicinity of the source depends on the inner structure of the source. Therefore, it is necessary to examine the distribution of source activity. As a method of the examination an auto-radiographic technique using several coloring materials for irradiation was tried. The materials used were “Radcolor film” developed by our center, besides a glass, polymethylmethacrylate (PMMA) and a blue cellophane.
Results showed that the autoradiography with Radcolor film is very useful to examine the position, the size and the activity difference of 60Co pieces by the change of color.