Toru MATUMOTOTakeshi A. IINUMATatuo ISHIKAWAYukio TATENONoboru KOSAKAYoshitaka OKADAKouzo MAKITAJunichi NISHIKAWAKikuo MACHIDAMasahiro IIOKazuhiko SETOKoichi UNOGuio UCHIYAMAYutaka MORIKenji KAWAKAMIYaeko TAKAGIAtushi KUBOYoshihisa AKIYAMANobuharu YUITetsuo NAKAJIMAHajime MURATAKiyoko KUSAKABEHiyoshimaru OYAMADA
Author information
JOURNAL FREE ACCESS

1985 Volume 34 Issue 9 Pages 486-492

Details
Abstract

The purpose of this study is to evaluate the clinical efficacy of liver SPECT (single photon emission computed tomography) . The two examinations were performed in 76 cases with SOL (space occupying lesion) and 58 normal cases. The results of the image reading by the planar image only (PS) and that of the image reading by the combination of PS and SPECT (PS+SPECT) were analyzed by ROC (receiver operating characteristic) analysis. The ROC curves showed that SPECT appears to reduce the number of results which were equivocal by the image reading of PS only. The detectability of SPECT for SOL in the left lobe of liver was less than that of PS without statistical significance. However, the performance of SPECT for SOL in the right lobe of liver was significantly better than that of PS.