RADIOISOTOPES
Online ISSN : 1884-4111
Print ISSN : 0033-8303
ISSN-L : 0033-8303
Dosimetry by a Cellulose Triacetate Film Dosimeter in Proton-beam Irradiation
Hiromi SUNAGATakashi AGEMATSURyuichi TANAKAKenzou YOSIDAIsao KOHNO
Author information
JOURNAL FREE ACCESS

1988 Volume 37 Issue 2 Pages 84-87

Details
Abstract

The basic characteristics of cellulose triacetate (CTA) film dosimeter have been investigated with 5, 8, and 15 MeV proton beams. The optical density change per unit absorbed dose for 8 and 15 MeV protons is the same as that given for electron beams, but a little smaller for 5 MeV protons. The CTA dosimeter was found to be useful to obtain dose distributions with high spatial resolution in samples exposed to proton beams.