[15O] 水注射液合成装置ARIS-O2を用いて製造したH215O注射液によるPET検査の臨床的有用性
畑澤 順関 宏恭下瀬川 恵久菅野 巖三浦 修一飯田 秀博竹越 襄上村 和夫
著者情報
ジャーナル フリー

1998 年 47 巻 5 号 p. 405-411

詳細
抄録

We evaluated the safety and clinical usefulness of cerebral and myocardial blood flow measurement by means of positron emission tomography (PET) with automated synthesis system of [15O] H2O (ARIS-02, JSW) in 62 patients with either brain disorder (n=31) or cardiac disease (n=31) . In all 62 patients, no side effects were detected after administering [15O] H2Ointravenously. The quality of the PET images were“fairly good”or“good”in all the cases. When compared with other imaging modalities such as computed tomography, this method provided physiological and functional information on the brain and cardiac diseases. We concluded that the PET measurement of cerebral and myocardial blood flow using automated synthesis system of [15O] H2Ois clinically useful.