河川技術論文集
Online ISSN : 2436-6714
江戸川におけるH-ADCPの流速連続モニタリング
二瓶 泰雄北山 秀飛江端 萌奈美色川 有
著者情報
ジャーナル フリー

2006 年 12 巻 p. 139-144

詳細
抄録

We have recently attempted to develop a new real-time monitoring system for river discharge with an H-ADCP (horizontal acoustic Doppler current profiler) measurement and numerical simulation. In the present paper, the field data for velocity measured with the H-ADCP in a main channel of the Edo River are introduced. The measuring accuracy of the H-ADCP is discussed with the comparison of river velocities obtained by the H-ADCP and the other measuring instrument like an ADCP. The observed result also indicates that the temporal and spatial variations of river velocity are dominant in a flood-flow condition, demonstrating the importance of measuring velocity profile at a horizontal line with the H-ADCP for evaluation of river discharge.