Neutral Point Bias Control Method for Large Capacity Inverter
Shigeo KAGAIkuo KAWAGUCHIAkinobu OKUIJun-ichi KITANO
著者情報
研究報告書・技術報告書 フリー

2000 年 41 巻 2 号 p. 52-56

詳細
抄録
A superconducting magnetic levitation system for high speed and mass transportation is being developed in Japan. Various types of running tests have already been carried out on the Yamanashi Maglev Test Line. We developed a large capacity Pulse Width Modulation (PWM) inverter as a power conversion system to drive Linear Synchronous Motors (LSM). To reduce the capacity required for the power conversion system, we installed a neutral point bias control system in the inverter for driving the LSM at the Yamanashi Maglev Test Line. This paper describes the results.
著者関連情報
© 2000 by Railway Technical Research Institute