Quarterly Report of RTRI
Online ISSN : 1880-1765
Print ISSN : 0033-9008
ISSN-L : 0033-9008
PAPERS
Reduction Method of Surge Voltage on AC Railcar's Body
Satoru HATSUKADE
著者情報
キーワード: grounding, SiC earth resistor, surge
研究報告書・技術報告書 フリー

2009 年 50 巻 2 号 p. 70-75

詳細
抄録
Surge voltage is created on AC railcar bodies when a train raises its pantograph or when its main circuit breaker is switched. This surge voltage expands and vibrates at the end car as a result of the reflection effect in distributed-parameter circuit theory. Extreme surge voltage causes damage to and malfunction of on-board equipment, especially electronic devices such as train signaling and brake control systems. This paper outlines the mechanism behind the phenomenon of surge generation on AC railcar bodies, outlines the results of experiments for improving AC railcar ground systems, and discusses ideal ground systems for the prevention of extreme surge voltage.
著者関連情報
© 2009 by Railway Technical Research Institute
前の記事 次の記事