金属表面技術
Online ISSN : 1884-3395
Print ISSN : 0026-0614
ISSN-L : 0026-0614
無電解銅メッキにおける自動濃度調節法の検討
無電解銅メッキに関する研究 (第3報)
広幡 兵伍老田 昌弘本城 克彦
著者情報
ジャーナル フリー

1970 年 21 巻 3 号 p. 142-146

詳細
抄録
An automatic regulating apparatus for pH and concentrations of copper and formaldehyde in electroless plating bath was manufactured for trial. The purpose of the apparatus was to maintain the concentrations of ingredients at constant during the deposition of copper.
The apparatus was used in the plating baths containing 0.02 and 0.03mol/l of copper ion and the deposition of copper for about 5hrs. was repeated 10 times.
In the bath containing 0.02mol/l of copper, the concentrations of copper ion and formaldehyde were maintained at 0.019-0.025 and 0.15-0.22mol/l, respectively, and pH was adjusted in the range of 12.0-12.3 during the operation.
The deposition rate of copper was likely to be increased with the number of repeating times of deposition. It would be due to the effects of HCO2- and SO42- which were accumulated during the repeated depositions.
Accordingly, the addtion amount of the ingredients must be controlled, but the operating time may be changed in order to keep a constant thickness of the deposit for each time of deposition.
著者関連情報
© (社)表面技術協会
前の記事 次の記事
feedback
Top