B-13 Development of measurement and evaluation method for SVOC : Part 1 Descriptions of the Measurement Method and Study of Measurement Conditions
Shin-ichi TANABETaisuke AOKIHideaki TANI
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract
Semi volatile organic compounds (SVOC) have high boiling points such as over 240 degrees Celsius. These high boiling points make it difficult to quantify SVOC concentrations with accuracy. In this study, the new measurement method was developed and descriptions of the method are shown in this paper. The method is evaluating SVOC amount by adsorbent amount to a glass plate, and to stabilize the amount the wind channel unit and fogging unit were developed. Also this paper reports the experiments to determine measurement conditions. It was found the wind channel unit stabilizes and increases the amount of SVOC adsorption to the plate.