日本鉱業会誌
Online ISSN : 2185-6729
Print ISSN : 0369-4194
粉塵抑制のための噴霧散水に関する基礎的研究
伊木 正二田尻 昭英
著者情報
ジャーナル フリー

1954 年 70 巻 792 号 p. 253-257

詳細
抄録

We have investigated drop-size distributions from centrifugal pressure nozzles, by changing water pressure and height of nozzles.
a) Quantity of water is proportional to the product of orifice diameter and square root of water pressure.
Q=348d0P
b) Spray cone angle is proportional to square root of water pressure below 3-4kg/cm2.
c) Average drop-size is inverse proportional to water pressure below 3-4kg/cm2.

著者関連情報
© The Mining and Materials Processing Institute of Japan
前の記事 次の記事