Food Hygiene and Safety Science (Shokuhin Eiseigaku Zasshi)
Online ISSN : 1882-1006
Print ISSN : 0015-6426
ISSN-L : 0015-6426
Notes
Determination of Hymexazol in Agricultural Products by GC-NPD
Yasuhiro TAMURAIchiro TAKANOMaki KOBAYASHISanae TOMIZAWAYukinari TATEISHINaoko SAKAIKyoko KAMIJOAkihiro IBEToshihiro NAGAYAMA
Author information
JOURNAL FREE ACCESS

2008 Volume 49 Issue 3 Pages 223-227

Details
Abstract

A method for the determination of hymexazol in agricultural produdcts by gas chromatography with a highly sensitive nitrogen-phosphorus detector (GC-NPD) was investigated. Hymexazol was extracted with acetonitrile, and the acetonitrile layer was separated by salting-out. The water layer was loaded onto a Chem-ElutTM column. Hymexazol in the water layer was adsorbed on the column, and eluted with ethyl acetate. The acetonitrile layer and the eluate were mixed and evaporated. The residue was dissolved in ethyl acetate, and the sample solution was cleaned up on a C18 column. Hymexazol in the eluate was analyzed by GC-NPD with a high-polarity capillary column (DB-FFAP) and highly deactivated inlet liner.
Recoveries of hymexazol spiked in agricultural products (tomato, lemon, soybean and other samples) at the level of 0.1 μg/g ranged from 65.0 to 84.7%. The limit of detection was 0.02μg/g.

Content from these authors
© 2008 Japanese Society for Food Hygiene and Safety
Previous article Next article
feedback
Top