Food Hygiene and Safety Science (Shokuhin Eiseigaku Zasshi)
Online ISSN : 1882-1006
Print ISSN : 0015-6426
ISSN-L : 0015-6426
Original papers
Determination of Cyromazine in Livestock Products by LC-MS/MS on an Anion-Cation Exchange Mode ODS Column
Yuki OkutomiHiroshi HayashiYoko MatsushimaYumi OhbaYukiko NakagawaHiroshi KoikeChieko NaganoKotaro SekimuraMaki Kanda Tsuneo Hashimoto
Author information
JOURNAL FREE ACCESS

2018 Volume 59 Issue 5 Pages 206-212

Details
Abstract

Cyromazine in livestock products was determined using a validated LC-MS/MS method. There are three key points in our methods. First, the extraction was performed with two solutions, methanol and pH 3.0 McIlvaine buffer. The process was optimized for each type of sample. Secondly, cleanup was performed using a reversed-phase and strong cation exchange mixed-mode cartridge. The cartridge was washed with 0.14% ammonium solution. Thirdly, the chromatographic separation was performed on an anion-cation exchange mode ODS column. There was no matrix effect on the extraction and determination for five livestock products. The quantification was carried out using an external standard calibration curve. This new method satisfies the Japanese guideline criteria. Recovery ranged from 77.2 to 92.1%, the relative standard deviation of repeatability (RSDr) was under 2.2%, and RSDwr was under 6.1%. Residual cyromazine was detected in raw milks and eggs.