Development and Evaluation of the Tin Point in the ITS-90
Koichi SatoJun TambaIsao KishimotoMasaru Arai
著者情報
会議録・要旨集 フリー

p. 229

詳細
抄録
The freezing point of tin, one of the temperature fixed-points defined in the ITS-90, is newly developed and evaluated. The temperature stability of the furnace is within ±1.5mK for 24 hours and temperature distribution is within 2mK over 20cm. To realize a stable plateau after a large amount of supercooling, the air blow cooling method is introduced instead of the conventional method. The temperature during the plateaus decreases only 0.3mK for 8 hours and a good repeatability within ±0.026mK is obtained in ten measurements.