Transactions of the Society of Instrument and Control Engineers
Online ISSN : 1883-8189
Print ISSN : 0453-4654
ISSN-L : 0453-4654
Paper
A High Sensitivity Bio Photosensor for Detecting a Luciferase Bioluminescence
Seiji KAMEDAYusuke MORIYAMAKenichi NODAAtsushi IWATA
Author information
JOURNAL FREE ACCESS

2011 Volume 47 Issue 1 Pages 25-30

Details
Abstract
A high sensitivity CMOS bio photosensor applicable to a bioluminescent assay was developed with a 0.18µm CMOS image sensor (CIS) process. The bio photosensor consisting of a photosensor and a PWM 20bit A/D converter achieved high sensitivity for detecting a extremely low bioluminescence due to a large photodiode area, a long exposure time and the other noise reduction techniques. The bio photosensor chip has a 2×4 sensor array on a 2.45×2.45mm2 die. Experimental results with the bioluminescence showed the chip can detect below 10-5lux luminescence at room temperature and the power consumption is 32µW.
Content from these authors
© 2011 The Society of Instrument and Control Engineers
Previous article Next article
feedback
Top