部分放電測定装置による低圧電動機の絶縁特性の測定
内海 権三平林 庄司渡辺 忠勝
著者情報
ジャーナル フリー

1981 年 17 巻 1 号 p. 118-124

詳細
抄録
Various nondestructive and breakdown tests were conducted with the two types of traction motors of electric locomotives of JNR which had been in service for many years. This paper describes nondestructive and breakdown characteristics. As the insulation resistance and tan δ are subject to environmental conditions such as humidity and temperature, we should be very careful to prevent their effect. On the other hand, the partial discharge characteristics are relatively little affected by the surrounding, also a considerable correlation is observed among the partial discharge characteristics and the breakdown voltage. This leads to the possibility of degradation judgement to a certain extent by the nondestructive test. The authors proposed the following guidelines for judging insulation detrioration in the partial discharge characteristics when the partial discharge measuring instruments are applied to an insulation test of relatively low voltage electric motor. (1) Partial discharge inception voltage (Vi): More than 1kV. Only for armature winding, more than 1.5kV. The windings which exhibit these test data have necessary insulation strength for operation. (2) Maximum partial discharge magnitude (Qmax): Below 10×10-9 coulomb. Only for armature winding, below 2×10-9 coulomb. The windings which exhibit these test data have necessary insulation strength for operation. (3) Partial discharge current(I): Below 3×104× 10-9A. Only for commutating pole winding, below 2×104×10-9A. The windings which exhibit these test data have necessary insulation strength for operation.
著者関連情報
© 社団法人 計測自動制御学会
前の記事 次の記事
feedback
Top