計測自動制御学会論文集
Online ISSN : 1883-8189
Print ISSN : 0453-4654
ISSN-L : 0453-4654
放射温度計校正用標準黒体炉
藤原 哲雄服部 晋菱刈 功清水 孝雄
著者情報
ジャーナル フリー

1987 年 23 巻 6 号 p. 558-564

詳細
抄録

A standard blackbody furnace for the calibration of commercially available radiation thermometers has been developed. This furnace has a cavity of chrome plated copper walls with an opening of 60mm in diameter. The furnace is designed so that the temperature of the cavity can be easily estimated by a resistance thermometer. It is shown that the furnace has an accuracy of 1K through the comparison with two fixed point blackbodies when the effective emissivity, the size-of-source effect and the absorption by water vapor of the air are corrected for.

著者関連情報
© 社団法人 計測自動制御学会
前の記事 次の記事
feedback