粉体工学研究会誌
Online ISSN : 1883-8766
ISSN-L : 0034-5156
光電型10チャンネル粒径弁別計数装置
牟田 典四郎
著者情報
ジャーナル フリー

1976 年 13 巻 7 号 p. 355-363

詳細
抄録
In order to study on the process of fracture of the projected shots, steel balls and glass beads, 10 channel counting apparatus was designed. This apparatus consisted of a photo electron type counter, pulse amplitude discriminators and counters for 10 channel counting.
Silicon photo diodes were applied as the converter, differential amplifiers as the discriminator, and electronic and electro-magnetic as the counter.
The apparatus counts the balls greater than 0.6mm O. D. at the rate of 555per second.
If the diameter difference of two balls is greater than 0.048d, both diameter of balls can be measured exactly, where d is the ball diameter.
The diameter frequency distribution of shots and glass beads obtained by the apparatus agrees approximately with that obtained by the projecter.
著者関連情報
© 粉体工学会
次の記事
feedback
Top