粉体工学会誌
Online ISSN : 1883-7239
Print ISSN : 0386-6157
ISSN-L : 0386-6157
懸濁液の噴霧乾燥における単核被覆粒子の回収率に及ぼす操作条件の影響
山田 則行安部 英一
著者情報
ジャーナル フリー

1998 年 35 巻 1 号 p. 18-24

詳細
抄録

The coating of fine particle was carried out by spray drying with a pneumatic nozzle. The raw powders that served as the core particles used in the experiments were particles with a narrow size distribution for polishing use. The coating material was ethyl cellulose dissolved in an ethanol and water mixture. The operating parameters were the composition of the suspensions, the concentration of ethyl cellulose and the core particle sizes. The recovery of single-core particles produced by spray drying was able to be formulated as a function of the operating parameters. The factor that most significantly influenced the recovery of single-core particles was particle size. The smaller the size, the less the single-core particles obtained. The thickness of the liquid film which adhered to the surface of a particle was estimated to be around 2.4μm.

著者関連情報
© 粉体工学会
前の記事 次の記事
feedback
Top