構造工学論文集 A
Online ISSN : 1881-820X
構造工学一般・計算力学
3次元熱伝導-熱応力解析による柱梁接合部の溶融亜鉛めっき割れ対策に関する検討
西尾 吉史岩崎 正二出戸 秀明大西 弘志
著者情報
ジャーナル フリー

2016 年 62A 巻 p. 32-41

詳細
抄録
Although hot dip galvanizing is a method of giving long-term corrosion protection to steel structures, steel materials may suffer cracks and/or distortion during hot dip galvanizing due to abrupt changes in temperature. As measures against cracks, beam-to-column welded connection with non-scallop methods having draining holes may be applied. However, there are some cases that cracks occurred in spite of taking such measures. Therefore, in this study, we carry out immersion tests into molten zinc using specimens which changed the diameter and the position of draining holes for the partial model that assumed beam-to-column welded connection. Furthermore, the measures that can reduce possibility of cracks are examined by using the three-dimensional thermal conductivity and elastic- plasticity thermal stress analysis.
著者関連情報
© 2016 公益社団法人 土木学会
前の記事 次の記事
Top