連結板ざぐり部の表面処理の仕様が皿型高力ボルト摩擦接合継手のすべり耐力に及ぼす影響
郎 宇林 厳山口 隆司加藤 大樹足立 健熊野 拓志吉田 賢二
著者情報
ジャーナル フリー

2021 年 67A 巻 p. 349-359

詳細
抄録

In order to improve durability of corrosion, previous studies reported that countersunk head bolts can be applied to high strength bolted friction grip joints. The surface treatment of the countersunk hole is specified to be inorganic zinc rich paint, if blasting of countersunk hole can be omitted in the construction site, the workability will improve. In this research, slipping test was carried out to evaluate the effect of surface treatment without blasting of countersunk hole on slip strength of friction grip joints with high strength countersunk head bolts. As a result, the effect of surface treatment of countersunk hole on slip strength is very small.