網谷 岳夫内田 大介平野 雄大豊原 匡織
著者情報
ジャーナル フリー

2023 年 69A 巻 p. 658-669

詳細
抄録

In this study, an axial force introduction test and a relaxation test were conducted to examine the nut rotation angle that keeps the introduced axial force of the F10T M30 high-strength bolt within the elastic range. Then, using the elastic region nut rotation method, we conducted an axial force introduction test assuming rainfall. As a comparative study, we assumed that the torque method and the conventional nut rotation method were used for tightening in rain, and investigated the effect of temperature and the presence or absence of lubricant during tightening on the introduced axial force.