27年供用した高力ボルト摩擦接合継手の残存軸力とすべり耐力に関する1考察
頼 健鵬佐倉 亮山口 隆司
著者情報
ジャーナル フリー

2023 年 69A 巻 p. 682-692

詳細
抄録

In this study, the authors measured the residual bolt tension and slip strength on the replaced brackets to investigate the performance of the high-strength bolted friction joints after 27 years of service. The results showed that the residual bolt tension of the paint-undamaged specimen was slightly lower than the design bolt tension, but less than half of the design bolt tension. In addition, the slip coefficient of the paint-damaged specimens is about 50% lower than the paint-undamaged specimen. It is due to changes in the faying surface's paint film thickness and roughness due to damage.