日本原子力学会和文論文誌
Online ISSN : 2186-2931
Print ISSN : 1347-2879
ISSN-L : 1347-2879
速報
TRAC-BF1 を用いた福島第一原発 1 号機の事故における非常用復水器の影響に関する検討
玉井 秀定秋本 肇高瀬 和之
著者情報
ジャーナル フリー

2012 年 11 巻 1 号 p. 8-12

詳細
抄録

  The Fukushima Daiichi Nuclear Plant Unit 1 accident was investigated with the TRAC-BF1 code in order to confirm the effect of an isolation condenser (IC) on core cooling analytically. The analysis shows that the formation of two-phase natural-circulation flow is a key phenomenon for core cooling. Therefore, it is too late to cool fuel rods, once the core is heated up because of the lack of coolant. It also shows that the early start-up of the IC is essential for avoiding the core meltdown under station blackout conditions.

著者関連情報
© 2012 一般社団法人 日本原子力学会
前の記事 次の記事
feedback
Top