日本原子力学会和文論文誌
Online ISSN : 2186-2931
Print ISSN : 1347-2879
ISSN-L : 1347-2879
論文
中間貯蔵容器を配置したモジュラー型遮蔽庫の合理的放射線遮蔽性能評価
浅見 光史大西 世紀川上 数雄松本 務小田野 直光
著者情報
ジャーナル フリー

2007 年 6 巻 4 号 p. 460-475

詳細
抄録

  This paper discusses a rational methodology to evaluate dose rate at the boundary of the interim storage facility using two methods; 1) a method taking into account “shade effect” which represents the self-shielding effect of interim storage containers, 2) utilization of a newly developed simplified code. It was proved that the method of the shade effect is applicable to the secondary gamma-ray, which dominates approximately 50% of the total effective dose rate. Thus, the effective dose rate attributed to the secondary gamma-ray depends on both the number of containers in the facility and the shade coefficient which represents the factor of the shade effect. Using this shade coefficient, the dose rate was estimated for the facility that stored 8 or 16 containers around the boundary of the facility and the results were consistent with that of the Monte Carlo calculation. In the present study, a simple neutron transport code, MCNP-ANISN_W, was newly developed aiming at the simplification of large-scale calculation. The results of the dose rate agreed well with that of the Monte Carlo calculation. The results of the present study show that the simple evaluation technique and the code developed in this study would be useful for the evaluation of dose rate around the boundary of the interim storage facility.

著者関連情報
© 2007 一般社団法人 日本原子力学会
前の記事 次の記事