鉄と鋼
Online ISSN : 1883-2954
Print ISSN : 0021-1575
ISSN-L : 0021-1575
論文
パイプラミナーヘッダにおける排水時間の定量化
杉原 広和上岡 悟史髙橋 秀行壁矢 和久
著者情報
ジャーナル オープンアクセス HTML

2017 年 103 巻 9 号 p. 528-533

詳細
抄録

Cooling equipment of the pipe laminar type is utilized on run-out tables in hot strip mills. It is known that the responsiveness of starting and stopping cooling water injection affects cooling accuracy. In this study, experiments and calculations were performed in order to research the water drainage behavior of pipe laminar type cooling equipment. The experimental apparatus consisted of a single nozzle, orifice, header and air inlet tube. The calculation model considered Bernoulli’s theorem and pressure loss. The experimental results showed that the pressure loss of the air inlet tube and the nozzle affects water drainage time. The calculated results showed good agreement with the experimental results. Therefore, it is possible to estimate the water drainage time of pipe laminar equipment by the developed calculation model. Based on the calculation model, we suggested that the optimum diameter of the air inlet tube is 12 mm.

著者関連情報
© 2017 一般社団法人 日本鉄鋼協会

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/