鉄鋼用X線断層撮影装置の開発
田口 勇中村 滋男
著者情報
ジャーナル オープンアクセス

1985 年 71 巻 14 号 p. 1685-1691

詳細
抄録
X-ray computed tomography is extensively used in medicine, but has rarely been applied to non-medical purposes. Steel specimens pose particularly difficult problems-very poor transmission of X-rays and the need for high resolving capability. There has thus been no effective tomographic method of examining steel specimens.
Due to the growing need for non-destructive, non-contact methods for observing and analyzing the internal conditions of steel microscopically, however, we have developed an X-ray Computed Tomographic Scanner for Steel (CTS) system, specifically for examination of steel specimens.
Its major specifications and functions are as follows. Type: the second-generation CT, 8-channels, Scanning method: 6° revolution, 30-times traversing, Slice width: 0.5 mm, Resolving capability: 0.25 × 0.25 mm, X-ray source: 420 kV, 3 mA, X-ray detector: BGO scintillator, Standard specimen shape: 50 mm dia., 100 mm high, Measuring time: 10.5 min.
Porosity of a stainless steel (SUS 304) bloom was examined three-dimensionally by the CTS system. Corrosion procedure of a steel slab was also examined.