鉄と鋼
Online ISSN : 1883-2954
Print ISSN : 0021-1575
ISSN-L : 0021-1575
赤外分光法を用いた高温ガスの"その場"分析とその応用
前田 正史高橋 昇桑野 芳一雀部 実柴田 耕一朗出口 幹郎稲葉 晉一
著者情報
ジャーナル フリー

1989 年 75 巻 2 号 p. 251-258

詳細
抄録

A technique for the "in-situ" analysis of the high temperature gases containing CO, CO2, H2O and SiO at 800-1 600°C was developed. The gas in the furnace was monitored by a newly developed infrared optical sensor with Fourier Transform Infrared Spectrometer (FTIR). The sensor was of a water cooled probe with various infrared light guide.
The experimental results could be summarized as follows;
(1) Partial pressure of CO, CO2 and H2O could be measured at 800-1600°C by the infrared optical sensor. The maximum sensitivity of this technique was as high as 0.0001atm (100ppm) of CO gas with optical depth of 200mm at 1 550°C.
(2) Infrared absorption spectrum of unstable SiO gas was measured by the infrared optical sensor demonstrating the possibility of measuring the partial pressure of SiO.
(3) It was demonstrated that those gas species evolved during the reduction of cold-bonded pellet by CO or H2 gas was quantitatively analyzed.
(4) "In-situ" analysis technique was applied to the pilot plant scale combustion test furnace. Change of gas composition with pulverized coal injection could be accurately monitored in the combustion furnace.

著者関連情報
© 一般社団法人 日本鉄鋼協会
前の記事 次の記事
feedback
Top