鉄と鋼
Online ISSN : 1883-2954
Print ISSN : 0021-1575
ISSN-L : 0021-1575
オージェ電子分光法定量分析における装置補正因子
源内 規夫広川 吉之助福田 安生鈴木 堅市橋本 哲鈴木 敏子薄木 智亮吉田 鎮男甲田 満瀬崎 博史堀江 浩田中 彰博大坪 孝至
著者情報
ジャーナル フリー

1992 年 78 巻 1 号 p. 165-172

詳細
抄録

This report is the result of a joint experiment on the quantitative analysis in Auger electron spectroscopy. The Auger intensity ratios of a high energy to a low energy for Al, Ni and Au varied by a factor of 2-3 among instruments, and as these ratios did not show a linear behavior with electron energy it was difficult to provide a universal expression for this behavior. Also, the variation of these ratios by the movement of an electron beam or the misplacement of a sample was not large enough to prove the spread among instruments. On the other hand, the voltage supply to a sample had a large influence on the low energy Auger intensity, and it was possible to reduce the spread of the data among instruments by selecting suitable voltages. But we could not obtain good results in the application of this method to the Fe-B-P alloy measurements.
Next, we discussed the method for correcting Auger peak intensity by utilizing the background intensity obtained from N(E) spectrum, and it was clarified that this method was effective for reducing the spread of the data among instruments and measuring conditions. We could obtain good results in the Fe-B-P alloy measurements by this method.

著者関連情報
© 一般社団法人 日本鉄鋼協会
前の記事 次の記事
feedback