The Tohoku Journal of Experimental Medicine
Online ISSN : 1349-3329
Print ISSN : 0040-8727
ISSN-L : 0040-8727
Regular Contributions
Deconvolution of Chemiluminescent Emission Curve Associated with Phagocytosis into Three Logarithmic Normal Distributions
Naoto OkazakiJuichi HirosawaNoriki SaitoToru Sato
Author information
JOURNAL FREE ACCESS

1998 Volume 185 Issue 4 Pages 271-280

Details
Abstract
The chemiluminescent emission reaction dependence on the activity of phagocytosis is well known. However, this method is not used to diagnostically in clinical assessment because the relationship between phagocytizing activity and chemiluminescent intensity has not been clearly established. Therefore, we attempted to analyze quantitatively the chemiluminescent emission curve by the phagocytosis of leukocytes. Mathematical assessment of the emission curve with respect to time was performed by fitting the curve to several regression models using the unweighed non-linear least squares method. A triple logarithmic normal distribution model provided a reasonable goodness of fit to the measured emission curve. The first component, about 5% of the calculated total counts, was assumed to arise from monocytes activity, the second component, about 20% from eosinocytes activity and the third component, up to 75%, from neutrophils activity. This method seems promising as a means for assaying whole blood without the need for pretreatment and for the providing a valid index that is independent of the technical differences between laboratories.
Content from these authors
© 1998 Tohoku University Medical Press
Previous article Next article