Transactions of the Materials Research Society of Japan
Online ISSN : 2188-1650
Print ISSN : 1382-3469
ISSN-L : 1382-3469
Evaluation of the removal efficiency of organic impurities by ECR plasma based on the ATR-FTIR analysis
Chongmu LeeWangwoo LeeHojin KimYoungjoon ChoHyoun Woo Kim
Author information
JOURNAL FREE ACCESS

2007 Volume 32 Issue 2 Pages 477-480

Details
Abstract
The removal efficiencies of organic impurities existing on the surface of silicon wafers by O2, H2, and N2O ECR plasma cleaning techniques were compared based on the Attenuated Total Reflection-Fourier Transform Infrared Spectroscopy (ATR-FTIR) analysis results. It was found that oxygen ECR plasma was the most efficient and hydrogen ECR plasma was the least efficient in removing organic impurities on Si wafers. In ECR oxygen plasma cleaning, the plasma exposure time to reach the detection limit of ATR-FTIR was 40s. Also the contaminants removal mechanism in O2, H2, and N2O ECR plasma cleaning have been discussed.