Transactions of the Materials Research Society of Japan
Online ISSN : 2188-1650
Print ISSN : 1382-3469
ISSN-L : 1382-3469
Developments for a Fluid Valve Using Magnetic Gels
Yuki HorikoshiTetsu MitsumataJun-ichi Takimoto
著者情報
キーワード: gels, magnetic gel, actuator, microvalve
ジャーナル フリー

2007 年 32 巻 3 号 p. 843-844

詳細
抄録
We have fabricated the fluid valve in a fluid tube of 800 micro m in diameter using magnetic gels. The magnetic gel was made from a network of poly(vinyl alcohol) crosslinked by glutaraldehyde and fine particles of iron oxide. When a weak magnetic field was applied to the valve, the valve came into a microtube and, as a result, a flow of water stopped. The valve opened and closed in response to the magnetic field generated by a permanent magnet. The valve worked well under the pressures of water from 0.3 MPa to 1.6 MPa.
著者関連情報
© 2007 The Materials Research Society of Japan
前の記事 次の記事
feedback