Transactions of the Materials Research Society of Japan
Online ISSN : 2188-1650
Print ISSN : 1382-3469
ISSN-L : 1382-3469
Regular Papers
Development of furnace temperature monitoring system using USB transducers
ZhangdanS. KambeN. KakizakiH. MizuguchiO. Ishii
著者情報
ジャーナル フリー

2011 年 36 巻 2 号 p. 191-194

詳細
抄録
Furnace temperature monitoring system with USB transducers was developed. The data were acquired automatically, transferred to PC, and analyzed. Temperatures of five points were measured simultaneously by the system. From the monitored temperatures, temperature distribution was drawn. When the set temperature is 500℃, the difference between set and real temperature is -45~+35℃. When the set temperature is 700℃, the difference between set and real temperature is -11.8~ +35.9℃. In the process of fine ceramics preparation such as high-TC superconductors, the difference between the set and real temperature should be controlled within ±5℃. The optimum area in the furnace was confirmed.
著者関連情報
© 2011 The Materials Research Society of Japan
前の記事 次の記事
feedback
Top