Calculation of Electromagnetic Field Emitted from UTP Cable by Moment Method from 0.3GHz to 2GHz
Nobuo KUWABARAYasuhiro ISHIDAMasato KAWABATA
著者情報
キーワード: UTP, radiation, wire grid
ジャーナル 認証あり

2009 年 E92.B 巻 6 号 p. 1974-1980

詳細
抄録
The electromagnetic field emitted from UTP cable has been calculated by the 4-port network method from 30MHz to 1GHz. However it has not been clarified as to whether this method was effective in the frequency range of more than 1GHz or not. In this paper, the electromagnetic field emitted from UTP cable was calculated by the moment method and it was compared with the calculated results by the 4-port network method. The wire grid model was developed to represent the propagation constants of UTP cable. The comparison of calculated and measured results confirms the validity of the model. A hybrid coupler was used to generate differential mode signal for the measurement. The comparison indicated that the calculated results by the moment method closely agreed with the measured results in the frequency range of 0.3 to 2GHz and the difference was smaller than the results by the 4-port network method.
著者関連情報
© 2009 The Institute of Electronics, Information and Communication Engineers