IEICE Transactions on Communications
Online ISSN : 1745-1345
Print ISSN : 0916-8516
Special Section on Advanced Electromagnetic Compatibility Technology in Conjunction with Main Topics of EMC'09/Kyoto
Evaluation of Uncertainties in Electromagnetic Disturbance Measurement above 1GHz due to Site Imperfections
Toshihide TOSAKAYukio YAMANAKA
Author information
JOURNAL RESTRICTED ACCESS

2010 Volume E93.B Issue 7 Pages 1690-1696

Details
Abstract

The data dispersion of the measurement of electromagnetic disturbance above 1GHz is mainly affected by site imperfections (expressed by the site voltage standing wave ratio (SVSWR)). To confirm the relationship between site imperfections and the measured field strength, we measured the SVSWR and the field strength radiated from the equipment under test (EUT) by changing the area covered by the RF absorber on the metal ground plane. From the results, we found that the data dispersion of measured field strength can be estimated from the measured SVSWR, and therefore, we can determine the measurement uncertainty of the measured field strength at the test site.

Content from these authors
© 2010 The Institute of Electronics, Information and Communication Engineers
Previous article Next article
feedback
Top