IEICE Transactions on Electronics
Online ISSN : 1745-1353
Print ISSN : 0916-8524

この記事には本公開記事があります。本公開記事を参照してください。
引用する場合も本公開記事を引用してください。

Effect of Surrounding Atmospheres on Break Arc Durations of Electrical Contacts in DC Load Conditions
Jiang WEILige ZHANGZhenbiao LIDandan ZHANGXiaoping BAIMakoto HASEGAWAQingcheng ZHU
著者情報
ジャーナル 認証あり 早期公開

論文ID: 2019ECP5001

この記事には本公開記事があります。
詳細
抄録

In order to realize better understanding of influential order sequences of surrounding atmospheres on break arc durations of electrical contacts in DC load conditions, a quantitative mathematical model, which aims to indicate dependences of break arc durations on several gas parameters such as molecular mass, viscosity, specific heat capacity, thermal conductivity, electro-negativity, and ionization potential, was analyzed. Break arc durations of AgCdO contact pairs were measured in several kinds of surrounding atmospheres (N2, Ar, He, air, O2 and CO2) under different DC voltage and current conditions, and data fitting processes were conducted. As a result, a candidate mathematical model was established, which could indicate possible influential order sequences of surrounding atmospheres on break arc durations in the range of the tested conditions.

著者関連情報
© 2019 The Institute of Electronics, Information and Communication Engineers
feedback
Top