IEICE Transactions on Electronics
Online ISSN : 1745-1353
Print ISSN : 0916-8524

この記事には本公開記事があります。本公開記事を参照してください。
引用する場合も本公開記事を引用してください。

Non-Arcing Circuit Breaking Phenomena in Electrical Contacts due to Dark Bridge
Hiroyuki Ishida
著者情報
ジャーナル 認証あり 早期公開

論文ID: 2019ECP5028

この記事には本公開記事があります。
詳細
抄録

In this paper, experimental data of non-arcing circuit breaking phenomena in electrical contacts are presented. A dark bridge that is a non-luminous bridge between electrical contacts is an effective factor for the non-arcing circuit break. A facility of a cantilever system was established to precisely control a position of an electrode. By using this facility, dark bridges between contacts were made and the dark bridges were observed by a microscopic camera system.

著者関連情報
© 2019 The Institute of Electronics, Information and Communication Engineers
feedback
Top