日本機械学会論文集
Online ISSN : 2187-9761
ISSN-L : 2187-9761
熱工学,内燃機関,動力エネルギーシステム
航空機の空調システム設計(第2報:直交流型熱交換器の解析モデル)
佐藤 理岩井 裕吉田 英生
著者情報
ジャーナル フリー

2019 年 85 巻 871 号 p. 18-00365

詳細
抄録

The purpose of this study is to develop an analytical model of cross-flow heat exchangers with offset strip fins which are usually equipped in the aircraft air conditioning system (so called the environmental control system, ECS). The ECS mainly consists of four cross-flow heat exchanges, i.e., a primary heat exchanger, a secondary heat exchanger, a reheater and a condenser. Because of the special requirements of the design for the aircraft, the primary and secondary heat exchangers are set adjoiningly; the reheater and the condenser are also set adjoingly. Therefore, in both the pairs, the effect of the temperature profile of the upstream component (the secondary heat exchanger or the reheater) on those of the downstream component (the primary heat exchanger or the condenser) should be taken into account for precise prediction of the system. To this end, a core element model was newly proposed in this study. In addition to the effect of temperature profile, phase changes (condensation and evaporation) of water included in the humid air simultaneously occur except for the primary heat exchanger. Regarding these phenomena, the method of sensible heat fraction (SHF) to convert the latent heat into the equivalent sensible heat was introduced, and the global and local SHF models were examined by comparison with the experiments. The prediction by these models were found to agree well with the actual performance of the ECS operations.

著者関連情報
© 2019 一般社団法人日本機械学会
前の記事 次の記事
feedback
Top