Magnetic Resonance in Medical Sciences
Online ISSN : 1880-2206
Print ISSN : 1347-3182
ISSN-L : 1347-3182
Volume 22, Issue 1
Displaying 1-14 of 14 articles from this issue
INNOVATIVE CLINICAL IMAGE
REVIEWS
  • Minghui Tang, Toru Yamamoto
    2023 Volume 22 Issue 1 Pages 7-25
    Published: 2023
    Released on J-STAGE: January 01, 2023
    Advance online publication: February 26, 2022
    JOURNAL OPEN ACCESS

    RF electromagnetic wave exposure during MRI scans induces heat and occasionally causes burn injuries to patients. Among all the types of physical injuries that have occurred during MRI examinations, RF burn injuries are the most common ones. The number of RF burn injuries increases as the static magnetic field of MRI systems increases because higher RFs lead to higher heating. The commonly believed mechanisms of RF burn injuries are the formation of a conductive loop by the patient’s posture or cables, such as an electrocardiogram lead; however, the mechanisms of RF burn injuries that occur at the contact points, such as the bore wall and the elbow, remain unclear. A comprehensive understanding of RF heating is needed to address effective countermeasures against all RF burn injuries for safe MRI examinations. In this review, we summarize the occurrence of RF burn injury cases by categorizing RF burn injuries reported worldwide in recent decades. Safety standards and regulations governing RF heating that occurs during MRI examinations are presented, along with their theoretical and physiological backgrounds. The experimental assessment techniques for RF heating are then reviewed, and the development of numerical simulation techniques is explained. In addition, a comprehensive theoretical interpretation of RF burn injuries is presented. By including the results of recent experimental and numerical simulation studies on RF heating, this review describes the progress achieved in understanding RF heating from the standpoint of MRI burn injury prevention.

    Download PDF (5253K)
  • Mika Kitajima, Hiroyuki Uetani
    2023 Volume 22 Issue 1 Pages 27-43
    Published: 2023
    Released on J-STAGE: January 01, 2023
    Advance online publication: March 23, 2022
    JOURNAL OPEN ACCESS
    Supplementary material

    Dynamic susceptibility contrast (DSC) and arterial spin labeling (ASL) are techniques used to evaluate brain perfusion using MRI. DSC requires dynamic image acquisition with a rapid administration of gadolinium-based contrast agent. In contrast, ASL obtains brain perfusion information using magnetically labeled blood water as an endogenous tracer. For the evaluation of brain perfusion in pediatric neurological diseases, ASL has a significant advantage compared to DSC, CT, and single-photon emission CT/positron emission tomography because of the lack of radiation exposure and contrast agent administration. However, in ASL, optimization of several parameters, including the type of labeling, image acquisition, background suppression, and postlabeling delay, is required, because they have a significant effect on the quantification of cerebral blood flow (CBF).

    In this article, we first review recent technical developments of ASL and age-dependent physiological characteristics in pediatric brain perfusion. We then review the clinical implementation of ASL in pediatric neurological diseases, including vascular diseases, brain tumors, acute encephalopathy with biphasic seizure and late reduced diffusion (AESD), and migraine. In moyamoya disease, ASL can be used for brain perfusion and vessel assessment in pre- and post-treatment. In arteriovenous malformations, ASL is sensitive to detect small degrees of shunt. Furthermore, in vascular diseases, the implementation of ASL-based time-resolved MR angiography is described. In neoplasms, ASL-derived CBF has a high diagnostic accuracy for differentiation between low- and high-grade pediatric brain tumors. In AESD and migraine, ASL may allow for accurate early diagnosis and provide pathophysiological information.

    Download PDF (14531K)
MAJOR PAPERS
  • Shinji Naganawa, Rintaro Ito, Mariko Kawamura, Toshiaki Taoka, Tadao Y ...
    2023 Volume 22 Issue 1 Pages 45-55
    Published: 2023
    Released on J-STAGE: January 01, 2023
    Advance online publication: October 16, 2021
    JOURNAL OPEN ACCESS

    Purpose: Peripheral retinal leakage (PRL) of contrast medium from the ora serrata (i.e., the peripheral part of the retina) was recently reported in normal eyes using ultra-widefield fluorescein angiography. We occasionally see PRL of gadolinium-based contrast agents (GBCAs) in the vitreous from the temporal and inferior sides of the ora serrata on MR images of subjects without ophthalmic disease. In this study, we retrospectively evaluated these MR images to determine if PRL was associated with aging. We also evaluated whether the initial leakage appeared in the temporal and inferior sides, and whether there was uniform distribution within the vitreous after 24 hours.

    Methods: In 127 subjects (9 volunteers, 85 patients with sudden deafness, and 33 patients with a suspicion of endolymphatic hydrops), pre- and post-contrast-enhanced heavily T2-weighted 3D-fluid attenuated inversion recovery (FLAIR) images were obtained. The presence or absence of PRL was subjectively evaluated. For patients with a suspicion of endolymphatic hydrops, 3D-real inversion recovery (IR) images were also obtained at pre-, 10 mins, 4 hours, and 24 hours after intravenous administration (IV) of GBCA. Four circular ROIs were placed in the vitreous humor and the signal intensity was measured.

    Results: In the cases with PRL (n = 88) and without PRL (n = 47), the median age was 59 and 47 years, respectively (P = 0.001). At 4 hours after IV-GBCA, the mean signal increase in the inferior temporal ROI was greater than all the other ROIs. At 24 hours after IV-GBCA, no significant difference in signal intensity was observed for the four ROIs.

    Conclusion: PRL of GBCA is age-dependent and occurs mainly from the inferior temporal side of the ora serrata. The contrast effect was uniformly distributed at 24 hours after IV-GBCA. Future observations in a variety of diseases will determine the clinical significance of these findings.

    Download PDF (6788K)
  • Akihiko Wada, Yuya Saito, Shohei Fujita, Ryusuke Irie, Toshiaki Akashi ...
    2023 Volume 22 Issue 1 Pages 57-66
    Published: 2023
    Released on J-STAGE: January 01, 2023
    Advance online publication: December 10, 2021
    JOURNAL OPEN ACCESS

    Purpose: Myelination-related MR signal changes in white matter are helpful for assessing normal development in infants and children. A rule-based myelination evaluation workflow regarding signal changes on T1-weighted images (T1WIs) and T2-weighted images (T2WIs) has been widely used in radiology. This study aimed to simulate a rule-based workflow using a stacked deep learning model and evaluate age estimation accuracy.

    Methods: The age estimation system involved two stacked neural networks: a target network-to extract five myelination-related images from the whole brain, and an age estimation network from extracted T1- and T2WIs separately. A dataset was constructed from 119 children aged below 2 years with two MRI systems. A four-fold cross-validation method was adopted. The correlation coefficient (CC), mean absolute error (MAE), and root mean squared error (RMSE) of the corrected chronological age of full-term birth, as well as the mean difference and the upper and lower limits of 95% agreement, were measured. Generalization performance was assessed using datasets acquired from different MR images. Age estimation was performed in Sturge–Weber syndrome (SWS) cases.

    Results: There was a strong correlation between estimated age and corrected chronological age (MAE: 0.98 months; RMSE: 1.27 months; and CC: 0.99). The mean difference and standard deviation (SD) were −0.15 and 1.26, respectively, and the upper and lower limits of 95% agreement were 2.33 and −2.63 months. Regarding generalization performance, the performance values on the external dataset were MAE of 1.85 months, RMSE of 2.59 months, and CC of 0.93. Among 13 SWS cases, 7 exceeded the limits of 95% agreement, and a proportional bias of age estimation based on myelination acceleration was exhibited below 12 months of age (P = 0.03).

    Conclusion: Stacked deep learning models automated the rule-based workflow in radiology and achieved highly accurate age estimation in infants and children up to 2 years of age.

    Download PDF (4046K)
  • Hirotaka Takita, Satoshi Doishita, Tetsuya Yoneda, Hiroyuki Tatekawa, ...
    2023 Volume 22 Issue 1 Pages 67-78
    Published: 2023
    Released on J-STAGE: January 01, 2023
    Advance online publication: January 26, 2022
    JOURNAL OPEN ACCESS
    Supplementary material

    Purpose: While amyloid-β deposition in the cerebral cortex for Alzheimer’s disease (AD) is often evaluated by amyloid positron emission tomography (PET), amyloid-β-related iron can be detected using phase difference enhanced (PADRE) imaging; however, no study has validated the association between PADRE imaging and amyloid PET. This study investigated whether the degree of hypointense areas on PADRE imaging correlated with the uptake of amyloid PET.

    Methods: PADRE imaging and amyloid PET were performed in 8 patients with AD and 10 age-matched normal controls. ROIs in the cuneus, precuneus, superior frontal gyrus (SFG), and superior temporal gyrus (STG) were automatically segmented. The degree of hypointense areas on PADRE imaging in each ROI was evaluated using 4-point scaling of visual assessment or volumetric semiquantitative assessment (the percentage of hypointense volume within each ROI). The mean standardized uptake value ratio (SUVR) of amyloid PET in each ROI was also calculated. The Spearman’s correlation coefficient between the 4-point scale of PADRE imaging and SUVR of amyloid PET or between the semiquantitative hypointense volume percentage and SUVR in each ROI was evaluated.

    Results: In the precuneus, a significant positive correlation was identified between the 4-point scale of PADRE imaging and SUVR of amyloid PET (Rs = 0.5; P = 0.034) in all subjects. In the cuneus, a significant positive correlation was identified between the semiquantitative volume percentage of PADRE imaging and SUVR of amyloid PET (Rs = 0.55; P = 0.02) in all subjects.

    Conclusion: Amyloid-β-enhancing PADRE imaging can be used to predict the SUVR of amyloid PET, especially in the cuneus and precuneus, and may have the potential to be used for diagnosing AD by detecting amyloid deposition.

    Download PDF (4828K)
  • Hirotaka Yamamoto, Mami Iima, Yo Kishimoto, Ayami Ohno Kishimoto, Sho ...
    2023 Volume 22 Issue 1 Pages 79-85
    Published: 2023
    Released on J-STAGE: January 01, 2023
    Advance online publication: March 04, 2022
    JOURNAL OPEN ACCESS

    Purpose: To evaluate whether readout-segmented echo-planar imaging (RS-EPI) diffusion-weighted imaging (DWI) can reduce image distortion and improve the lesion identification in parathyroid adenomas (PTAs) compared to single-shot EPI (SS-EPI) DWI, and to determine whether PTAs can be differentiated from other soft tissue structures of the head and neck region by using the apparent diffusion coefficient (ADC) value.

    Methods: We retrospectively analyzed the preoperative MR images including DWI of 24 patients with surgically confirmed PTA. RS-EPI and SS-EPI DWI were evaluated by two independent readers for the identification of the lesions and distortion. The ADC values of the PTAs were compared with those of thyroid glands and cervical lymph nodes.

    Results: RS-EPI provided significantly less distortion compared to SS-EPI. RS-EPI tended to have better lesion identification compared with SS-EPI without a statistically significant difference. On SS-EPI, the PTAs had significantly higher ADC values compared with the cervical lymph nodes. On RS-EPI, the PTAs had significantly higher ADC values compared with the thyroid glands and cervical lymph nodes.

    Conclusion: RS-EPI reduces the DWI distortion in PTAs. The ADC value obtained using RS-EPI enables the differentiation of PTAs from nearby structures, such as thyroid glands and cervical lymph nodes.

    Download PDF (4215K)
  • Akinori Yamaguchi, Kohsuke Kudo, Ryota Sato, Yasuo Kawata, Niki Udo, M ...
    2023 Volume 22 Issue 1 Pages 87-94
    Published: 2023
    Released on J-STAGE: January 01, 2023
    Advance online publication: March 10, 2022
    JOURNAL OPEN ACCESS

    Purpose: Studies on quantitative susceptibility mapping (QSM) have reported an increase in magnetic susceptibilities in patients with Alzheimer’s disease (AD). Despite the pathological importance of the brain surface areas, they are sometimes excluded in QSM analysis. This study aimed to reveal the efficacy of QSM analysis with brain surface correction (BSC) and/or vein removal (VR) procedures.

    Methods: Thirty-seven AD patients and 37 age- and sex-matched, cognitively normal (CN) subjects were included. A 3D-gradient echo sequence at 3T MRI was used to obtain QSM. QSM images were created with regularization enabled sophisticated harmonic artifact reduction for phase data (RESHARP) and constrained RESHARP with BSC and/or VR. We conducted ROI analysis between AD patients and CN subjects who did or did not undergo BSC and/or VR using a t-test, to compare the susceptibility values after gray matter weighting.

    Results: The susceptibility values in RESHARP without BSC were significantly larger in AD patients than in CN subjects in one region (precentral gyrus, 8.1 ± 2.9 vs. 6.5 ± 2.1 ppb) without VR and one region with VR (precentral gyrus, 7.5 ± 2.8 vs. 5.9 ± 2.0 ppb). Three regions in RESHARP with BSC had significantly larger susceptibilities without VR (precentral gyrus, 7.1 ± 2.0 vs. 5.9 ± 2.0 ppb; superior medial frontal gyrus, 5.7 ± 2.6 vs. 4.2 ± 3.1 ppb; putamen, 47,8 ± 16.5 vs. 40.0 ± 15.9 ppb). In contrast, six regions showed significantly larger susceptibilities with VR in AD patients than in CN subjects (precentral gyrus, 6.4 ± 1.9 vs. 4.9 ± 2.7 ppb; superior medial frontal gyrus, 5.3 ± 2.7 vs. 3.7 ± 3.3 ppb; orbitofrontal cortex, –2.1 ± 2.7 vs. –3.6 ± 3.2 ppb; parahippocampal gyrus, 0.1 ± 3.6 vs. –1.7 ± 3.7 ppb; putamen, 45.0 ± 14.9 vs. 37.6 ± 14.6 ppb; inferior temporal gyrus, –3.4 ± 1.5 vs. –4.4 ± 1.5 ppb).

    Conclusion: RESHARP with BSC and VR showed more regions of increased susceptibility in AD patients than in CN subjects. This study highlights the efficacy of this method in facilitating the diagnosis of AD.

    Download PDF (3767K)
  • Sho Maruyama, Sayuri Tatsuo, Soichiro Tatsuo, Saya Iida, Fumiyasu Tsus ...
    2023 Volume 22 Issue 1 Pages 95-101
    Published: 2023
    Released on J-STAGE: January 01, 2023
    Advance online publication: March 17, 2022
    JOURNAL OPEN ACCESS

    Purpose: The human primary auditory cortex is located in the Heschl’s gyrus (HG). To assess the intrinsic MR property in the gray matter of the HG (GM-HG) with T1 and T2 values using a commercially available MR fingerprinting (MRF) technique.

    Methods: The subjects were 10 healthy volunteers (with 20 HGs; mean age, 31.5 years old; range, 25–53 years old). Coronal T1 and T2 maps were obtained with commercially available MRF using a 3-Tesla MR system. Two radiologists measured the T1 and T2 values of the GM-HG, the GM in the superior temporal gyrus (GM-STG), and the GM in the middle temporal gyrus (GM-MTG) by drawing a ROI on coronal maps.

    Results: For both radiologists, the mean T1 and T2 values of the GM-HG were significantly lower than those in the GM-STG or GM-MTG (P < 0.01). The interobserver reliability using the intraclass correlation coefficients (ICC) (2,1) showed strong agreement for the measurement of the T1 and T2 values (ICCs =⃥ 0.80 and 0.78 for T1 and T2 values, respectively).

    Conclusion: The T1 and T2 values on MRF for the GM-HG were lower than those for the GM-STG and GM-MTG, likely reflecting a higher myelin content and iron deposition in the GM-HG. Quantitative measurements using the MRF can clarify cortical properties with high reliability, which may indicate that MRF mapping provides new insights into the structure of the human cortical GM.

    Download PDF (2844K)
TECHNICAL NOTES
  • Michiru Kajiwara, Tomoyuki Haishi, Dwi Prananto, Susumu Sasaki, Ryohei ...
    2023 Volume 22 Issue 1 Pages 103-115
    Published: 2023
    Released on J-STAGE: January 01, 2023
    Advance online publication: December 10, 2021
    JOURNAL OPEN ACCESS
    Supplementary material

    23Na-MRI provides information on Na+ content, and its application in the medical field has been highly anticipated. However, for existing clinical 1H-MRI systems, its implementation requires an additional broadband RF transmitter, dedicated transceivers, and RF coils for Na+ imaging. However, a standard medical MRI system cannot often be modified to perform 23Na imaging. We have developed an add-on crossband RF repeater system that enables 23Na-MRI simply by inserting it into the magnet bore of an existing 1H MRI. The three axis gradient fields controlled by the 1H-MRI system were directly used for 23Na imaging without any deformation. A crossband repeater is a common technique used for amateur radio. This concept was proven by a saline solution phantom and in vivo mouse experiments. This add-on RF platform is applicable to medical 1H MRI systems and can enhance the application of 23Na-MRI in clinical usage.

    Download PDF (15082K)
  • Yusuke Ayabe, Kohei Hamamoto, Yoshikazu Yoshino, Yoshimasa Ikeda, Emik ...
    2023 Volume 22 Issue 1 Pages 117-125
    Published: 2023
    Released on J-STAGE: January 01, 2023
    Advance online publication: December 11, 2021
    JOURNAL OPEN ACCESS
    Supplementary material

    A flow-diverter (FD) device is a well-established tool for the treatment of unruptured intracranial aneurysms. Time-of-flight (TOF) MR angiography (MRA) is widely used for postoperative assessment after the treatment with FD; however, it cannot fully visualize intra-aneurysmal and intrastent flow signals due to the magnetic susceptibility from the FD. Recently, the utility of MRA with ultra-short TE (UTE) sequence and arterial spin labeling technique in assessing the therapeutic efficacy of intracranial aneurysms treated with metallic devices has been reported, but long image acquisition time is one of the drawbacks of this method. Herein, we introduce a novel UTE MRA using the subtraction method that enables the reduction in susceptibility artifacts with a short image acquisition time.

    Download PDF (4307K)
  • Masayuki Yamaguchi, Kosuke Kojo, Mizuki Akatsuka, Tomoyuki Haishi, Tat ...
    2023 Volume 22 Issue 1 Pages 127-136
    Published: 2023
    Released on J-STAGE: January 01, 2023
    Advance online publication: March 23, 2022
    JOURNAL OPEN ACCESS
    Supplementary material

    We have developed a new device, consisting of a 3-cm RF coil and an immobilizer, to acquire high-resolution MR images of the testis. With the approval of our institutional review board, we conducted an MRI study on a cohort of healthy volunteers to test this device. With the participants in the supine position, we placed the dedicated immobilizer and RF coil on the scrotum for typically no more than 3 min. Subsequently, T2-weighted images were acquired with an in-plane resolution of 117 µm using a 3-T MR scanner and the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) sequence. The total scan time ranged from 12 to 30 min (average 20 min). High-resolution MR images of the testis were acquired without deterioration by motion artifacts. Our results showed that the combined use of a small RF coil and an immobilizer is a feasible option for acquiring high-resolution MR images of the testis.

    Download PDF (8833K)
BRIEF COMMUNICATIONS
  • Koichi Oshio
    2023 Volume 22 Issue 1 Pages 137-141
    Published: 2023
    Released on J-STAGE: January 01, 2023
    Advance online publication: October 13, 2021
    JOURNAL OPEN ACCESS

    Although the glymphatic system hypothesis is highly popular, it also lacks certain details. In this paper, an attempt was made to present a more clearly defined hypothesis, which is consistent with the past experiment results. The new hypothesis consists of (1) water flux in the brain parenchyma, (2) water and solutes pathway of the perivascular space, and (3) maintenance of this pathway by the network of astrocytes.

    Download PDF (4916K)
  • Shinji Naganawa, Rintaro Ito, Toshiaki Taoka, Tadao Yoshida, Michihiko ...
    2023 Volume 22 Issue 1 Pages 143-146
    Published: 2023
    Released on J-STAGE: January 01, 2023
    Advance online publication: December 25, 2021
    JOURNAL OPEN ACCESS

    It has been reported that perivenous cystic structures near the parasagittal dura are associated with the leakage of gadolinium-based contrast agents at 4 hours after intravenous administration. The origin of such cystic structures remains unknown. While reading many cases of MR cisternography, we noticed that some of the cystic structures appeared to connect to the perivenous subpial space. This new imaging finding might facilitate future research of the waste clearance system for the central nervous system.

    Download PDF (3091K)
feedback
Top